MAINTENANCE MANUAL > Adjustment > Adjustment Items > Temperature control Upper limit value setting
Model
SWJ-320S
Issued 2012.07.19 Revised

4.2.24 Temperature control Upper limit value setting

 Outline
Setting the upper limit value of temperature control when shipped, to the upper limit value of this machine.
Upper limit value: 70°C (applied to the Post-, Pre- and Print heater)
 Setting procedure
Power ON
PV
2 4
SV
5 0
[SET] and [<] simultaneously pressing (more than 3 sec)
PV
C o d
SV
0 0 0 0
PV
C o d
SV
0 0 0 1
PV
S L H
SV
0 4 0 0
PV
S L H
SV
0 0 7 0
PV
S L L
SV
0 0 0 0
PV
2 4
SV
5 0
 Checking of setting
Power ON
0 0
PV
7 0
SV
© 2013 MIMAKI ENGINEERING CO.,LTD.
F/W ver
Current temperature
Set temperature
Control key
1. Turn the power ON.
2. Shift in the setting mode by pressing [SET] and [<] for more
than 3 seconds simultaneously.
3. Set "0000" to "0001" by pressing [^].
4. Press [SET].
5. Set it to "0070" (Upper limit temperature) by pressing [^], [v]
and [<].
6. Press [SET].
7. End the setting mode by pressing [SET] and [<] for 3 seconds
simultaneously.
1. Check that the initial indication is "70" (at shipment: 400) by
switching the power switch of heater from "OFF" to "ON".
1.0
Remark
4.2.24
Rev.
1.0
1
2
3
4
5
6
7
8
R.1.0
P.1