MAINTENANCE MANUAL > Adjustment > Adjustment Items > Temperature control Upper limit value setting
Model
SWJ-320S
Issued 2012.07.19 Revised
4.2.24 Temperature control Upper limit value setting
Outline
Setting the upper limit value of temperature control when shipped, to the upper limit value of this machine.
Upper limit value: 70°C (applied to the Post-, Pre- and Print heater)
Setting procedure
Power ON
PV
2 4
SV
5 0
[SET] and [<] simultaneously pressing (more than 3 sec)
PV
C o d
SV
0 0 0 0
PV
C o d
SV
0 0 0 1
PV
S L H
SV
0 4 0 0
PV
S L H
SV
0 0 7 0
PV
S L L
SV
0 0 0 0
PV
2 4
SV
5 0
Checking of setting
Power ON
0 0
PV
7 0
SV
© 2013 MIMAKI ENGINEERING CO.,LTD.
F/W ver
Current temperature
Set temperature
Control key
1. Turn the power ON.
2. Shift in the setting mode by pressing [SET] and [<] for more
than 3 seconds simultaneously.
3. Set "0000" to "0001" by pressing [^].
4. Press [SET].
5. Set it to "0070" (Upper limit temperature) by pressing [^], [v]
and [<].
6. Press [SET].
7. End the setting mode by pressing [SET] and [<] for 3 seconds
simultaneously.
1. Check that the initial indication is "70" (at shipment: 400) by
switching the power switch of heater from "OFF" to "ON".
1.0
Remark
4.2.24
Rev.
1.0
1
2
3
4
5
6
7
8
R.1.0
P.1