MAINTENANCE MANUAL > Adjustment > Mechanical Adjustment > Positioning of the Encoder Sensor
Model
SWJ-320S
Issued 2012.07.19 Revised
4.3.6 Positioning of the Encoder Sensor
Outline
Adjust the position of the encoder sensor.
Proceed with the work after well confirmed the following processes in advance.
Procedure
Encoder sensor
Encoder scale
1~2.5 mm
Center
OK
NG
Lens
Scale is contact-
ing with the top.
Scale holder
Encoder scale
© 2013 MIMAKI ENGINEERING CO.,LTD.
1. Loosen the screws on the sensor BKT.
Screw
2. Adjust the position of encoder PCB assy., and fix it with the
screws.
Screw
3. Check the followings, moving the carriage with hands from the
NG
right end of main body to the left end.
• The upper part of the encoder scale is not in touch with the
sensor.
• The exposed lens of the sensor is not over the height of the
encoder scale.
Lens is exposed.
• Check if the encoder sensor is contacting with the scale
holder.
F/W ver
1.0
Remark
Rev.
1.0
1
2
3
4
5
6
7
8
4.3.6
R.1.0
P.1