MAINTENANCE MANUAL > Disassembly and Reassembly > Heater relations > Temperature controller
Model
SWJ-320S
Issued 2012.07.19 Revised
6.8.1 Temperature controller
Outside of Left electrical box cover
POST
PRE
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Additionally, if electric charges are still remaining, it may cause damage to electronic parts or the like.
 Work procedures
Mounting adapter
Widen the hook
PRINT
PRE
Wiring diagram
Terminal diagram viewed from the
backside of controller
© 2013 MIMAKI ENGINEERING CO.,LTD.
PRINT
1. Turn off the main power supply and remove the power plug
from the main body.
2. Open the left electrical BOX cover.
3. Disconnect all of the cables connected on the backside of con-
troller.
4. Remove the mounting adapter by widening the top and bottom
hook parts of mounting adapter by a flat-blade screwdriver or
the like and pulling it to the front direction.
Temperature controller
5. Reverse the disassembly procedure for reassembly.
POST
At connecting, connect them surely, referring to the table below.
PRINT
Terminal No. Wire marker Terminal No. Wire marker
PRE
Terminal No. Wire marker Terminal No. Wire marker
POST
Terminal No. Wire marker Terminal No. Wire marker
F/W ver
Remark
Inside of Left electrical box cover
PRINT
1
A36
2
A37
3
––
4
17
5
16
10
1
A33
2
A34
3
––
4
15
5
14
10
1
A30
2
A31
3
––
4
13
5
12
10
Rev.
1.0
POST
PRE
6
––
7
––
8
RT3
9
RT33
––
6
––
7
––
8
RT2
9
RT22
––
6
––
7
––
8
RT1
9
RT11
––
6.8.1
R.1.0
1
2
3
4
5
6
7
8
P.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swj-320 s4

Table of Contents