MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > ID Contact PCB CN032 Simple assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
6.4.12 ID Contact PCB CN032 Simple assy.
 Work Procedures
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
ID contact PCB
Screw
ID PCB socket
ID contact PCB
Hooks (4 positions)
ID PCB socket
© 2013 MIMAKI ENGINEERING CO.,LTD.
ID Contact PCB CN032 simple assy.
1. Turn off the main power supply and remove the power plug
from the main body.
2. Open the cover CoverRS.
3. Disconnect the connector from the ID contact PCB.
Disconnect
the connector.
4. Unscrew the screw, and remove the ID PCB socket together
with the ID contact PCB.
5. Widen the hooks of ID PCB socket, and remove the ID contact
PCB.
6. Reverse the disassembly procedure for reassembly.
F/W ver
Remark
Rev.
1.0
1
2
3
4
5
6
7
8
6.4.12
R.1.0