Model SWJ-320S Issued 2012.07.19 Revised 2012.12.14 F/W ver
7.1.2 List of Error Messages
 List of Error Messages ?5/5?
No.
LCD
ERROR 62a
INK EXPIRATION(2M)
47
ERROR 618
TANKlevelH :1234
48
ERROR 61b
SUPPLY INK:1234
49
ERROR 707
!HD HEATER BRK
50
ERROR 901
51
INVALID OPERATION
ERROR 902
DATA REMAIN
52
ERROR 909
PARAMETER VERSION
53
ERROR 04
PARAM ROM
54
© 2013 MIMAKI ENGINEERING CO.,LTD.
Cause
Ink expiration date has passed
(more than two months ago).
Sub-tank sensor abnormality
(Though a certain amount was consumed,
there is no change in the sub-tank sensor.)
Ink filling into the sub-tank has failed.
Is the heater of the head disconnected?
(The temperature does not rise after heat-
ing for over a certain period of time.)
Operation error.
(You performed an invalid operation.)
Drawing data is remaining.
The version of DOWNLOAD parameter
differs from that of F/W.
Access Error of the PARAMETER ROM
1.The state that cannot access "FROM" on
the MAIN PCB.
2.The state that cannot access "EEPROM"
on the Central-IO PCB.
Remark
1.0
List of Countermeasures
1. Replace it with a new ink bottle and perform charging.
2. If the error occurs even if the ink expiration date has not
passed, reset the date from [#ADJUST] -> [TIME SET] and
restart.
1. With [#TEST SENSOR], check the detection status of the
target liquid level detection sensor. (Also, visually check
the float position in the sub-tank.)
2. From [#TEST AGEING] -> [PUMP MOTOR], discharge
ink in the sub-tank to the bottom.
From [#TEST AGEING] -> [INK SUPPLY], check
that sending ink is performed.
*If sending ink cannot be performed: The supply
pump, the cartridge valve and the UISS valve shall
be replaced.
1. Check the room temperature is not too low.
2. Replace the Print Head with a new
3. Replace the HDC PCB with a new one.
(Carry out the followings if the error still occurs when
data is cleared.)
1. Check errors in the parameter.
2. Remove USB cable from the printer and execute data clear.
-> If solved, it is a problem on USB cable or PC.
3. Replace the USB Cable with a new one.
4. Replace the MAIN PCB with a new one.
1. Check whether the F/W version at uploading parameters
matches the F/W version of the machine.
2. If the F/W version of the machine is older, perform
parameter DOWNLOAD again after upgrading the version.
1. Replace the FFC and cable located between the HDC PCB
and the MAIN PCB.
2. Replace the FFC and cable located between the HDC PCB
and the MAIN PCB.
3. Replace the Central-IO PCB with a new
4. Replace the MAIN PCB with a new
Rev.
1.1
1
2
3
one.
(Refer to 3.3.1)
(Refer to 6.4.7)
4
5
(Refer to 3.3.1)
6
one.(Refer to 6.4.6)
one.(Refer to 3.3.1)
7
8
7.1.2