 List of Error Messages ?3/5?
No.
LCD
ERROR 19d
HDC V36 [12__]
29
ERROR 1a1
INK SUP PMP [12__]
30
ERROR 201
31
COMMAND
ERROR 202
PARAMETER
32
ERROR 304
33
USB INIT ERR
ERROR 305
USB TIME OUT
34
ERROR 401
35
MOTOR X
ERROR 403
X CURRENT
36
ERROR 402
37
MOTOR Y
ERROR 404
Y CURRENT
38
© 2013 MIMAKI ENGINEERING CO.,LTD.
Cause
Control error to HDC PCB voltage
Voltage of the HDC PCB that displayed
number on the LCD is lower than pre-
scribed voltage.
Voltage of the ink supply pump can not be
set it to the prescribed voltage.
Command error
Other data than commands is received
Parameter error
Parameter out of the numeral value range
is received
USB initialization error
(Failures in initializing USB device)
USB time-out
(Occurrence of time-out error on USB
device)
X Servo error
(Excessive load to the X-motor)
X-motor current
(Over current error of X-motor is detected.)
Y Servo error
(Excessive load to the Y-motor)
Y-motor current
(Over current error of Y-motor is detected.)
Remark
1.0
List of Countermeasures
1. Check the output pressure of the DC power supply (36V)
and the DC power supply (5V).
2. Replace the HDC PCB with a new one.
3. Replace the power supply above.
4. Replace the MAIN PCB with a new one.
1. Check if there is no parameter error?
2. Check the output pressure of the DC power supply (36V)
and the DC power supply (5V).
3. Replace the power supply above.
4. Replace the CIO PCB with a new one.
5. Replace the MAIN PCB with a new one.
1. Check if the output set of the PC matches the set of the
machine side?
2. Change the profile.
3. Check if there is no parameter error?
4. Check if there is no trouble on the USB Cable?
5. Replace the USB Cable.
6. Replace the MAIN PCB with a new one.
1. Check if there is no parameter error?
2. Replace the USB Cable.
3. Replace the MAIN PCB with a new one.
1. Check if there is no error on the print data.
(Check if the same error occurs on other data?)
2. Check if there is no trouble on the Timing Belt.
3. Check if there is no trouble on the Motor Cable.
(disconnecting, burnout, or the like)
4. Check the FFC between each PCB and Short-connectors
connected on the PCB.
5. Replace the X-axis Motor with a new
1. Check if there is no error on the print data.
(Check if the same error occurs on other data?)
2. Check if it moves to the Y-direction smoothly in the power-
off condition.
3. Check if there is no trouble on the Timing Belt.
4. Check if there is no trouble on the Motor Cable.
(disconnecting, burnout, or the like)
5. Check the FFC between each PCB and Short-connectors
connected on the PCB.
6. Replace the Y-axis motor with a new one.