Memory Check - MIMAKI SWJ-320 S2 Maintenance Manual

Hide thumbs Also See for SWJ-320 S2:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Test Items > Test Function > MEMORY CHECK
Model
SWJ-320S
Issued 2012.07.19 Revised

5.1.3 MEMORY CHECK

 Outline
Checks each memory of the machine.
 Content
Item
S-RAM check
Executes Read/Write check of S-RAM.
 When a DATA error occurs, "S-RAM D:xxxxxxxx" is displayed.
 When a Address error occurs, "S-RAM A:xxxxxxxx" is displayed.
F-ROM check
Executes hash check of F-ROM.
 When a check sum error occurs, "F-ROM SUM ERROR" is displayed.
SDRAM check
Executes Read/Write check of SDRAM.
 When a DATA error occurs, "SDRAM D:xxxxxxxx" is displayed.
 When a Address error occurs, "SDRAM A:xxxxxxxx" is displayed.