MAINTENANCE MANUAL > Workflow > Electrical Parts > Replacement of the 180 LPI Encoder Sensor
Model
SWJ-320S
Issued 2012.07.19 Revised
3.3.6 Replacement of the 180 LPI Encoder Sensor
List of replacement procedures
Item
Covers
Power OFF
1.
Removal of covers, etc.
2.
Encoder Sen-
Encoder Sensor replacement
3.
sor
Check/
Encoder position adjustment
4.
Adjustment
Power ON
5.
Encoder check
6.
Covers
Mounting of the covers.
7.
For the power OFF, be sure to turn the main power OFF.
If the sleep function works accidentally during the operation, it is very dangerous.
© 2013 MIMAKI ENGINEERING CO.,LTD.
180 LPI Encoder Sensor
Work operation
Turning the main power OFF.
* Be sure to turn the main power OFF since the power
Remove the following covers.
Carriage cover
SD PCB cover
Checking the encoder mounting at the specified position.
Turning the power ON to start the machine.
Carry out the encoder check to confirm it functions nor-
mally.
Mount the covers that have been removed.
F/W ver
Remark
Description
comes ON due to the sleep control if turned to OFF by
the power SW on the panel.
Rev.
1.0
1
2
3
Ref.
---
4
6.1.1
6.4.4
5
4.3.6
---
5.1.9
6
6.1.1
7
8
3.3.6
R.1.0