6.7.2 Take-up Slack Sensor assy.
Take-up Slack Sensor assy.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Additionally, if electric charges are still remaining, it may cause damage to electronic parts or the like.
 Work procedures
Terminal block
Take-up Slack
Relay socket
Sensor assy.
Loosen the screw.
Take-up Slack Sensor assy.
Take-up Slack
Sensor assy.
Sensor
BKT
Screw(x2)
© 2013 MIMAKI ENGINEERING CO.,LTD.
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the following covers.
Loosen the screw.
• Feeding/take-up left side cover
3. Remove the terminal block cover, and disconnect the sensor
cables (A4, A21) from the terminal block, loosening the screw.
4. Disconnect the sensor cable (A25) from the relay socket termi-
nal, loosening the screw.
5. Loosen the screws, and remove the take-up slack sensor cover.
Loosen the screw.
6. Remove the sensor BKT from the main body.
7. Remove the take-up slack sensor assy. from the sensor BKT.
8. Reverse the disassembly procedure for reassembly.
F/W ver
Remark
If the sensor mounting angle is shifted by replac-
ing or removing the sensor, perform the angle
adjustment.
(See
4.3.7 Slack sensor Optical axis