6.3.1 X-axis Motor assy.
 Work procedures
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode func-
tions mistakenly during the operation.
Proceed with the work after well confirmed the following processes in advance.
3.2.1 Replacement of the X-axis Motor
X belt
Loosen
X-motor BKT2
X-axis motor
Screw
© 2013 MIMAKI ENGINEERING CO.,LTD.
1. Turn off the main power supply.
2. Loosen the screws fixing the X-motor BKT2 to make the belt
tension free, and then remove the X-belt from the X-drive pul-
ley.
X drive pulley
3. Open the cover LR, and disconnect the connector.
4. Remove the X-axis Motor from the X-motor BKT2.
5. Reverse the disassembly procedure for reassembly.
F/W ver
Remark
Remove it paying attention to the motor dropping.