MAINTENANCE MANUAL > Electrical Parts > Circuit Board Specifications > Central IO PCB assy.
Issued 2012.07.19 Revised
Model
SWJ-320S

2.3.4 Central IO PCB assy.

 Outline
Unit name: Central IO PCB assy.
MounteFeeding slack sensord position: Electrical box
 Main specifications
Pump motor, Wiper motor, Sensor, Suction fan (etc.) are connected.
 List of Connectors
Parts No.
Pin
CN1
10
CN2
10
CN3
20
CN4
3
CN5
16
CN6
16
CN7
9
CN8
8
CN9
30
CN10
12
CN11
5
CN12
10
CN13
12
CN14
20
CN16
12
CN17
20
CN18
4
CN20
3
*For the details of connecting destinations, refer to the block diagram.
© 2013 MIMAKI ENGINEERING CO.,LTD.
Connected to:*
Not use
Not use
EPL Main PCB assy.
Stop switch
Not use
Not use
Not use
Ink pressurizing part, Suction fan
Wiper sensor,
X-axis origin sensor,
Y origin sensor,
Feeding slack sensor
Suction fan, Ink pressurizing part
ID contact PCB CN032 assy.
Not use
Pump Motor
Ink pump, Ink pressurizing part
Pump Motor, Wiper Motor
Not use
Not use
Cascade short 13 assy.
F/W ver.
Remark
Connecting desti-
nation CN
Spare
Connector is not mounted.
CN9
Spare
Spare
For Debug
Spare
STM3, 4 (S4 only)
STM1, 2, 5
Spare
Rev.
1.0
1
2
3
4
Remarks
5
6
7
8
2.3.4
R.1.0