MIMAKI SWJ-320 S2 Maintenance Manual page 150

Hide thumbs Also See for SWJ-320 S2:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Central-IO PCB assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
6.4.6 Central-IO PCB assy.
After turning off the sub and main power switches, unplug the power cord. Make sure to take15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high voltage applied to the high-power part
of the DC power supply assy. Take care to avoid contact with it.
Proceed with the work after well confirmed the following processes in advance.
3.3.5 Replacement of the Central-IO PCB assy.
 Work procedures
Screw (x4)
Central-IO PCB assy
© 2013 MIMAKI ENGINEERING CO.,LTD.
F/W ver
1. Turn off the main power supply and remove the power plug
from the main body.
2. Open the cover RRU.
3. Disconnect all connectors on PCB.
4. Remove the Central-IO PCB assy.
5. Reverse the disassembly procedure for reassembly.
Remark
6.4.6
Rev.
1.0
1
2
3
4
5
6
7
8
R.1.0
P.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swj-320 s4

Table of Contents