MIMAKI SWJ-320 S2 Maintenance Manual page 190

Hide thumbs Also See for SWJ-320 S2:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model SWJ-320S Issued 2012.07.19 Revised 2012.12.14 F/W ver
7.1.4 List of SYSTEM HALT
 List of SYSTEM HALT ?1/4?
No.
LCD
SYSTEM HALT (*)
35 V Power recovery error
104 : +35V RECVR
1
SYSTEM HALT (*)
F-ROM CLEAR error (F-ROM clear unable)
10e :FROM CLEAR
F-ROM is not clearable on Parameter writ-
2
ing, FW down loading and Log clearing.
(fls_secclr)
SYSTEM HALT (*)
FROM WRITE error (F-ROM writing
10f : FROM WRITE
unable)
3
F-ROM is not clearable on Parameter writ-
ing, FW down loading and Log clearing.
(fls_secclr)
SYSTEM HALT (*)
No Keyboard PCB
110 : PCB KEY
4
SYSTEM HALT (*)
The F1 fuse on the MAIN PCB went out.
5
115 : PCB MAIN-F1
SYSTEM HALT (*)
The F2 fuse on the MAIN PCB went out.
6
116 : PCB MAIN-F2
SYSTEM HALT (*)
The F3 fuse on the MAIN PCB went out.
7
117 : PCB MAIN-F3
SYSTEM HALT (*)
No Slider PCB.
8
11f : PCB SLIDER
SYSTEM HALT (*)
LCD thermistor IC RW error
120 : LCD THERM.
9
SYSTEM HALT (*)
No PRAM
10
122 : PRAM NONE
SYSTEM HALT (*)
PRAM data error
11
123 : PRAM DATA
SYSTEM HALT (*)
PRAM address error
12
124 : PRAM ADDR
SYSTEM HALT (*)
EEPROM read trouble
13
125 : EEPROM READ
CIO Register (EER:Address 74) bit6
SYSTEM HALT (*)
EEPROM write trouble
126 : EEPROM WR
CIO Register (EER:Address 74) bit7
14
© 2013 MIMAKI ENGINEERING CO.,LTD.
1.0
Cause
1. Replace the DC Power Supply(36V) PCB with a new one.
(Refer to 6.4.2)
2. Replace the MAIN PCB with a new one.
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the MAIN PCB with a new one.
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the MAIN PCB with a new one.
1. Check the connections between the Keyboard PCB and the
MAIN PCB and then disconnect and connect the FFCs.
2. Replace the FFCs of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the MAIN PCB with a new one.
1. Replace the MAIN PCB with a new one.
1. Check the connections between the Keyboard PCB and the
MAIN PCB, and then disconnect and connect the FFCs.
2. Replace the FFCs and the cabeles of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the MAIN PCB with a new one.
5. Replace the DC Power Supply(5V) with a new one.
(Refer to 6.4.5)
1. Update F/W.
2. Replace the PRAM PCB with a new one.
3. Replace the MAIN PCB with a new one.
1. Update F/W.
2. Upload the parameter and initialize parameter with
#PARAMETER.
3. Check the connection state between MAIN PCB - Central-
IO PCB.
4. Replace the MAIN PCB with a new one.
5. Replace the Central-IO PCB with a new one.
Remark
Corrective Measures
Rev.
1.1
(Refer to 3.3.1)
1
(Refer to 3.3.1)
2
(Refer to 3.3.1)
3
(Refer to 3.3.1)
(Refer to 3.3.1)
4
5
(Refer to 3.3.1)
(Refer to 6.4.8)
6
(Refer to 3.3.1)
7
(Refer to 3.3.1)
(Refer to 6.4.6)
8
7.1.4
R.1.1
P.1