MIMAKI SWJ-320 S2 Maintenance Manual page 158

Hide thumbs Also See for SWJ-320 S2:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Suction Fan Controller assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
6.4.14 Suction Fan Controller assy.
Outside of Left electrical box cover
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
 Work Procedures
Suction power adjustment knob
Connetor 1
Cooling fan
Suction fan con-
troller assy.
Spacer bolt(x4)
© 2013 MIMAKI ENGINEERING CO.,LTD.
Suction fan controller assy.
1. Turn off the main power supply and remove the power plug
2. Pull out the suction power adjustment knob to the front direc-
Nut
3. Remove the nut of the suction fan controller shaft part.
4. Open the left electrical BOX cover.
Screw(x4)
5. Remove all connectors of the suction fan controller assy.
6. Remove the screw, and remove the cooling fan.
Connetor 2
7. Unscrew the spacer bolts, and remove the suction fan controller
8. Reverse the disassembly procedure for reassembly.
F/W ver
Remark
Inside of Left electrical box cover
Suction fan controller assy.
from the main body.
tion.
assy.
Rev.
1.0
1
2
3
4
5
6
7
8
6.4.14
R.1.0
P.1

Advertisement

Table of Contents
loading

This manual is also suitable for: