Name (index 6):
The Name returns a string value in ASCII format, containing the name of the parameter.
Example:
In this example, the master reads the name of par. 0-01, Language.
The following telegram must be sent to the adjustable frequency drive:
STX
LGE
02
0E
STX =
02 Start byte
LGE =
0E Length of remaining telegram
ADR =
Sends the adjustable frequency drive on Address 1, Danfoss format
PKE =
4001; 4 in the PKE field indicates a Read Parameter Description and 01 indicates par. 0-01,
Language
IND =
0006; 6 indicates that Names is required.
The response from the adjustable fre-
quency drive will be:
STX
LGE
02
12
PKE =
3001; 3 are the response for Name and 01 indicates the par. 0-01, Language
IND =
00 06; 06 indicates that Name is sent.
PVA =
4C 41 4E 47 55 41 47 45
L A N G U A G E
The parameter value channel is now set up to a visible string which returns an ASCII
character for each letter in the parameter name.
Lower limit (index 7):
The Lower limit returns the minimum allowed value of a parameter. The data type of
Lower limit is the same as for the parameter itself.
*
default setting
( )
display text
How to Program
7
6
30
29
2
2
2
22
2
21
2
14
2
13
2
6
2
5
ADR
PKE
IND
01
40 01
00 06
ADR
PKE
IND
01
30 01
00 06
[ ]
value for use in communication via serial communication port
MG.33.B6.22 - VLT is a registered Danfoss trademark
5
4
3
28
27
26
2
2
2
2
20
2
19
2
18
2
12
2
11
2
10
2
4
2
3
2
2
PWE
PWE
HIGH
LOW
00 00
00 00
PVA
4C41 4E47 5541 4745
2
1
25
24
2
2
ms
2
17
2
16
2
9
2
8
2
1
2
0
PCD1
PCD2
BCC
XX XX
XX XX
XX
PCD1
PCD2
BCC
XXXX
XXXX
XX
293

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents