FC 300 Design Guide
Motor connection ≤ 10 HP [7.5 kW] IP 55
All types of three-phase asynchronous standard
motors can be connected to the FC 300. Normally,
small motors are star-connected (230/400 V, D/Y).
Large motors are delta-connected (400/690 V,
D/Y). Refer to the motor nameplate for correct
connection mode and voltage.
NOTE
In motors without phase insulation paper or other insulation reinforcement suitable for operation
with voltage supply (such as adjustable frequency drive, fit an LC filter on the output of the FC 300.
No.
96
U
U1
W2
U1
No.
99
PE
How to Install
97
98
Motor voltage 0-100%
V
W
of AC line voltage.
3 wires out of motor
V1
W1
6 wires out of motor, Delta-connected
U2
V2
V1
W1
6 wires out of motor, Star-connected
U2, V2, W2 to be interconnected separately
(optional terminal block)
Ground connection
MG.33.B6.22 - VLT is a registered Danfoss trademark
14.75-29.5 HP [11-22 kW] IP 21