Danfoss FC 300 Design Manual page 267

Vlt automationdrive
Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

FC 300 Design Guide
16-** Data readouts
"
Par.
Parameter description
No. #
16-0* General status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status word
16-05 Main actual value [%]
16-1* Motor status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor voltage
16-13 Frequency
16-14 Motor current
16-16 Torque
16-17 Speed [RPM]
16-18 Motor thermal
16-3* Drive status
16-30 DC link Voltage
16-32 Brake energy /s
16-33 Brake energy /2 min
16-34 Heatsink temp.
16-35 Inverter thermal
16-36 InomVLT
16-37 ImaxVLT
16-38 SL controller state
16-39 Controlcard temp.
16-5* Ref. & feedb.
16-50 External reference
16-51 Pulse reference
16-52 Feedback [Unit]
16-6* Inputs & outputs
16-60 Digital input
16-61 Terminal 53 switch setting
16-62 Analog input 53
16-63 Terminal 54 switch setting
16-64 Analog input 54
16-65 Analog output 42 [mA]
16-66 Digital output [bin]
16-67 Freq. input #29 [Hz]
16-68 Freq. input #33 [Hz]
16-69 Pulse output #27 [Hz]
16-70 Pulse output #29 [Hz]
16-8* Fieldbus & FC port
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm. option STW
16-85 FC port CTW 1
16-86 FC port REF 1
16-9* Diagnosis Readout
16-90 Alarm word
16-92 Warning word
16-94 Extended status word
*
default setting
( )
How to Program
Drive dependent
Drive dependent
display text
[ ]
value for use in communication via serial communication port
MG.33.B6.22 - VLT is a registered Danfoss trademark
Default value
4-set-up
0
All set-ups
0.000 Unit
All set-ups
0.0 %
All set-ups
0
All set-ups
0
All set-ups
0.0 kW
All set-ups
0.00 hp
All set-ups
0.0 V
All set-ups
0.0 Hz
All set-ups
0.00 A
All set-ups
0.0 Nm
All set-ups
0 RPM
All set-ups
0 %
All set-ups
0 V
All set-ups
0.0 HP
All set-ups
0.0 HP
All set-ups
0 °C
All set-ups
0 %
All set-ups
All set-ups
All set-ups
0
All set-ups
0 °C
All set-ups
0.0
All set-ups
0.0
All set-ups
0.000
All set-ups
0
All set-ups
[0] Current
All set-ups
0.000
All set-ups
[0] Current
All set-ups
0.000
All set-ups
0.000
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All-setups
0
All-setups
Change
Conver-
Type
during
sion index
operation
FALSE
0
V2
FALSE
-3
Int32
FALSE
-1
Int16
FALSE
0
V2
FALSE
0
N2
FALSE
2
Uint32
FALSE
-2
Uint32
FALSE
-1
Uint16
FALSE
-1
Uint16
FALSE
-2
Uint32
FALSE
-1
Int16
FALSE
67
Int32
FALSE
0
Uint8
FALSE
0
Uint16
FALSE
0
Uint32
FALSE
0
Uint32
FALSE
100
Uint8
FALSE
0
Uint8
FALSE
-2
Uint16
FALSE
-2
Uint16
FALSE
0
Uint8
FALSE
100
Uint8
FALSE
-1
Int16
FALSE
-1
Uint32
FALSE
-3
Int32
FALSE
0
Uint16
FALSE
-
Uint8
FALSE
-3
Int32
FALSE
-
Uint8
FALSE
-3
Int32
FALSE
-3
Int16
FALSE
0
Int16
FALSE
0
Int32
FALSE
0
Int32
FALSE
0
Int32
FALSE
0
Int32
FALSE
0
V2
FALSE
0
N2
FALSE
0
V2
FALSE
0
V2
FALSE
0
N2
FALSE
0
Uint32
FALSE
0
Uint32
FALSE
0
Uint32
267

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents