Danfoss FC 300 Design Manual page 260

Vlt automationdrive
Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

FC 300 Design Guide
5-** Digital In/Out
"
Par.
Parameter description
No. #
5-0* Digital IO mode
5-00
Digital I/O mode
5-01
Terminal 27 mode
5-02
Terminal 29 mode
5-1* Digital inputs
5-10
Terminal 18 digital input
5-11
Terminal 19 digital input
5-12
Terminal 27 digital input
5-13
Terminal 29 digital input
5-14
Terminal 32 digital input
5-15
Terminal 33 digital input
5-3* Digital outputs
5-30
Terminal 27 digital output
5-31
Terminal 29 digital output
5-4* Relays
5-40
Function relay
5-41
On delay, relay
5-42
Off delay, relay
5-5* Pulse input
5-50
Term. 29 low frequency
5-51
Term. 29 high frequency
5-52
Term. 29 low ref./feedb. value
5-53
Term. 29 high ref./feedb. value
5-54
Pulse filter time constant #29
5-55
Term. 33 low frequency
5-56
Term. 33 high frequency
5-57
Term. 33 low ref./feedb. value
5-58
Term. 33 high ref./feedb. value
5-59
Pulse filter time constant #33
5-6* Pulse output
5-60
Terminal 27 pulse output variable
5-62
Pulse output maximum frequency #27
5-63
Terminal 29 pulse output variable
5-65
Pulse output maximum frequency #29
5-7* 24V encoder input
5-70
Term 32/33 encoder resolution
5-71
Term 32/33 encoder direction
default setting
( )
display text
*
260
How to Program
Default value
[0] PNP
[0] Input
[0] Input
[8] Start
[10] Reverse
[2] Coast inverse
[14] Jog
[24] Set-up select bit 1
[23] Set-up select bit 0
[0] No operation
[0] No operation
[0] No operation
0.01 s
0.01 s
100 Hz
100 Hz
0.000 Unit
1500.000 Unit
100 ms
100 Hz
100 Hz
0.000 Unit
1500.000 Unit
100 ms
[0] No operation
5000 Hz
[0] No operation
5000 Hz
1024
[0] Clockwise
[ ]
value for use in communication via serial communication port
MG.33.B6.22 - VLT is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint16
-
Uint8