FC 300 Design Guide
Function:
Enter the station address in this parameter or
alternatively in the hardware switch. In order
to adjust the station address in par. 9-18, the
hardware switch must be set to 126 or 127 (i.e.
all switches set to 'on'). Otherwise this parameter
will display the actual setting of the switch.
9-22 Telegram Selection
Option:
Standard telegram 1
PPO 1
PPO 2
PPO 3
PPO 4
PPO 5
PPO 6
PPO 7
*
PPO 8
Function:
Select a standard Profibus telegram configuration
for the frequency converter, as an alternative
to using the freely configurable telegrams
in par. 9-15 and 9-16.
9-23 Parameters for Signals
Array [1000]
Option:
None
3-02 Minimum Reference
3-03 Maximum Reference
3-12 Catch Up/Slow Down Value
3-41 Ramp 1 Ramp Up Time
3-42 Ramp 1 Ramp Down Time
3-51 Ramp 2 Ramp Up Time
3-52 Ramp 2 Ramp Down Time
3-80 Jog Ramp Time
3-81 Quick Stop Ramp Rime
4-11 Motor Speed Low Limit
4-13 Motor Speed High Limit
4-16 Torque Limit Motor Mode
4-17 Torque Limit Generator Mode
8-90 Bus Jog 1 Speed
8-91 Bus Jog 2 Speed
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
*
default setting
( )
display text
How to Program
[1]
[101]
[102]
[103]
[104]
[105]
[106]
[107]
[108]
This parameter contains a list of signals available
for selection in par. 9-15 and 9-16.
[ ]
value for use in communication via serial communication port
MG.33.B6.22 - VLT is a registered Danfoss trademark
16-05 Main Actual Value [%]
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor Current
16-16 Torque
16-17 Speed [RPM]
16-18 Motor Thermal
16-19 KTY Sensor Temperature
16-20 Phase Angle
16-30 DC Link Voltage
16-32 Brake Energy / s
16-33 Brake Energy / 2 Min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-38 SL Controller State
16-39 Controlcard Temp.
16-50 External Reference
16-51 Pulse Reference
16-52 Feedback [Unit]
16-53 Digi Pot Reference
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
16-63 Terminal 53 Switch Setting
16-64 Analog Input 54
16-65 Analog Output 42 [mA]
16-66 Digital Output [bin]
16-67 Freq. Input #29 [Hz]
16-68 Freq. Input #33 [Hz]
16-69 Pulse Output #27 [Hz]
16-70 Pulse Output #29 [Hz]
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm Option STW
16-85 FC Port CTW 1
16-90 Alarm Word
16-91 Alarm Word 2
16-92 Warning Word
16-93 Warning Word 2
16-94 Extended Status Word
16-95 Extended Status Word 2
Function:
217