user password-history
Configures the maximum number of old passwords to retain in the password history.
user password-history number
Syntax Definitions
number
Defaults
parameter
number
Platforms Supported
OmniSwitch 6250
Usage Guidelines
•
Specify 0 with this command to disable the password history function.
•
The user is prevented from specifying any passwords that are recorded in the password history and fall
within the range configured through this command.
•
The password history value is specified as part of a global password policy that is applied to all pass-
words when they are created or modified.
Examples
-> user password-history 2
-> user password-history 0
Release History
Release 6.6.1; command was introduced.
Related Commands
show user password-policy
MIB Objects
aaaAsaConfig
aaaAsaPasswordHistory
page 43-40
The maximum number of old passwords to retain.
The range is 0 to 24.
default
4
Displays the global password policy configuration for the switch.
OmniSwitch 6250 CLI Reference Guide
AAA Commands
November 2009