7.9.6

External Signal Interface (EXT)

This interface complies with IEEE1284 standard.
Basic Specifications
Connector
Signal Levels
Connector Pin Specifications
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
*
236
CL4NX Operator Manual
Centronics IDC Type 14 pin (female)
High-level
: +4.2 to +5.0 V
Low-level
: +0.0 to +0.7 V
7
14
I/O
Output
Outputs a low signal when paper end is detected.
-
Reference Signal Ground
Output
Outputs a low signal when ribbon end is detected.
Output
Outputs a low signal when the error such as head open error is
detected.
Input
Prints one label when a low signal is detected.
Output
Outputs a signal when the label print is completed.
Input
Prints the same label again when a low signal is detected.
Input
External power supply: 5 V
Output
Outputs a low signal when the printer changes to offline mode.
Output
Outputs a high signal when ribbon near end is detected.
-
-
-
+24 V ± 10%
-
Vcc +5 V
-
-
Output
Outputs a low signal when the dispense is completed.
You can set the pin number for output through Interface in Menu.