GAP Slice Level
Printing > Advanced > Calibrate > GAP Slice Level
Set the slice level of Gap sensor.
The setting procedures are as follows:
1. Use the formula as follows to calculate the slice level.
[(High level - Low level) x 0.3 + Low level = slice level]
2. Select the Gap Slice Level in Auto-calibration menu and press the
button.
/
3. Press the
arrow buttons to change the Slice level value. Set
the Slice level to the slice level calculated in step 1.
4. Press the right soft button to confirm the value.
Note:
If you set the Slice Level to 0.0 (V), the printer sets the slice level automat-
ically.