4 Operation and Configuration
Outputs
Interface > External I/O > Signals > Outputs
Set the output pin No. of the signal.
/
Press the
change and then press the
Press the
button to save the settings and goes back to Signals menu.
The setting items are as follows:
1
Paper End
2
Ribbon End
3
Machine Error
4
Print Done
5
Qty/Offline
6
Ribbon Near End
7
Dispenser
The options for each signal outputs are as follows:
• OUT_PIN1: Set the selected signal to 1PIN.
• OUT_PIN3: Set the selected signal to 3PIN.
• OUT_PIN4: Set the selected signal to 4PIN.
• OUT_PIN6: Set the selected signal to 6PIN.
• OUT_PIN9: Set the selected signal to 9PIN.
• OUT_PIN10: Set the selected signal to 10PIN.
• OUT_OFF: Set the selected signal to off mode.
Note:
You cannot set the any outputs with same output pin No. If do, the settings
will show in red and you cannot save the settings.
126
CL4NX Operator Manual
arrow buttons to highlight the item that you want to
/
arrow buttons to change the pin No.
Set the output pin No. of Signal Paper End.
Set the output pin No. of Signal Ribbon End.
Set the output pin No. of Signal Machine Error.
Set the output pin No. of Signal Print Done.
Shows Qty if you have selected MODE1 in
EXT 9PIN menu.
Shows Offline if you have selected MODE2 in
EXT 9PIN menu.
Set the output pin No. of Signal Qty/Offline.
Set the output pin No. of Signal Ribbon Near
End.
Set the output pin No. of Signal Dispenser.
*Dispenser unit or Linerless cutter unit should
be connected to use this signal.