4 Operation and Configuration
GAP Levels
Printing > Advanced > Calibrate > GAP Levels
Set the level of Gap sensor manually.
The setting procedures are as follows:
1. Firstly, adjust the "Low" level (voltage) of the Gap sensor.
2. Remove the label away from the liner.
3. Pass the liner through the media sensor. Align so that the media sen-
sor does not sense the I-mark (black mark).
4. Close the print head. To get the correct adjustment result, adjust after
you have closed the print head.
5. Select the Gap Levels in Auto-calibration menu and press the
button.
/
6. Press the
Sensor value is below 0.5(V). Set the Emit value as low as possible.
7. If the Sensor value does not decrease below 0.5 after you changed
the Emit value, press the
value.
8. Record the Sensor value got from the above procedures. This is the
value of "Low" level for Gap sensor.
Next, check the "High" level (voltage) of the Gap sensor with the proce-
dures as follows:
9. Pass the media (attached with liner) through the media sensor. Align
so that the media sensor does not sense the I-mark (black mark).
10. Close the print head.
11. Check the Sensor value.
If the value is 1.0(V) higher than the "Low" level value you have
recorded, then this is the value of "High" level for Gap sensor.
If the difference of "High" and "Low" level is less than 0.9, adjust the
Emit and Receive value so that the difference is more than 1.0, or
adjust again from step 1.
12. The standard value of "High" and "Low" level for Gap sensor are as fol-
lows:
• Low (with only liner) ≥ 0.5 (V)
• High (media attached with liner) - Low ≥ 1.0 (V)
13. If both "High" and "Low" level obey the standard value, press the right
soft button to confirm the value.