Firing order
Injection pump
Injector
Nozzle holder
Nozzle
Injector setting pressure
Injection pump timing adjustment: pump piston
travel with cylinder no.1 at TDC
stage)
Engine idle speed
Top engine speed with no load
(*) Signal injector installed on cylinder no. 1
T U R B O C H A R G I N G Turbocharger operated by exhaust gases with waste-gate pressure valve and air/air
heat exchanger (intercooler)
Turbocharger: type
Maximum turbo boost pressure
Engine: fuel system and turbocharging
Ifl^S) TO 100 BHP
LUCAS DPC-FT09,
electronic
LUCAS
LCD 011R02AA1 (*)
LCR 6705344
LUCAS RND 05DC6897
143-150 bar
(compression
Electronic adjustment
870-930/min
4920-5020/min
< 1.05 bar
Technical data
iC^S)
TD 75 BHP
1-3-4-2
BOSCH, mechanical
VER-679
BOSCH
BOSCH KCA 30S41
BOSCH DN 0 SD 321
150-158 bar
0.92 mm
830-870/min
5000-5100/min
Garrett GT 15
0.950 bar
Cross section through
turbocharger
4A007A02
OO.io