Suzuki GSX-R1000 Service Manual page 251

Hide thumbs Also See for GSX-R1000:
Table of Contents

Advertisement

Manuals by Motomatrix / The Solution For Lost Motorcycle Coded Keys
5) Disconnect the respective vacuum hoses (2) from
vacuum nipples on the throttle body.
6) Disconnect the IAP sensor coupler (3).
7) Connect the respective vacuum tester hoses (4) to
the vacuum nipples.
8) Set up the SDS tool. (Refer to the SDS operation
manual for further details.)
14) Click "ON" button (6) to fix the ISC air volume of four cylinders.
NOTE
When making this synchronization, be sure that the engine coolant temperature is within 80 – 100 °C
(176 – 212 °F).
"A": Engine speed: Approx 1 150 rpm
email: info@motomatrix.co.uk / www.motomatrix.co.uk
3
2
I947H1140309-01
4
I947H1140310-01
"A"
"B"
9) Start the engine.
10) Click "Data monitor".
11) Warm up the engine (Engine coolant temp. more
than 80 °C (176 °F)).
12) Click "Active control".
13) Click "ISC air volume control" (5).
"B": ISC valve position: Approx 48 step
Engine Mechanical:
1D-17
I947H1140311-01
5
I947H1140300-02
6
I947H1140312-01