Suzuki GSX-R1000 Service Manual page 185

Hide thumbs Also See for GSX-R1000:
Table of Contents

Advertisement

Manuals by Motomatrix / The Solution For Lost Motorcycle Coded Keys
Step
4
1) Turn the ignition switch OFF.
2) Connect the EXCVA coupler.
3) Set up the SDS tools. Refer to "Self-Diagnostic
Procedures" (Page 1A-12).
4) Turn the ignition switch ON.
5) Click "Exhaust valve operating control" (1).
6) Click "Full closed" (2).
7) Insert the needle pointed probes into the back side of the
EXCVA coupler (3). ((+) Y – (–) W)
8) Measure the EXCVA position sensor output voltage at
EXCV fully closed position.
Special tool
(A): 09900–25008 (Multi circuit tester set)
(B): 09900–25009 (Needle-point probe set)
Tester knob indication
Voltage (
)
EXCVA position sensor output voltage
EXCV is fully closed: 0.45 – 1.4 V
((+) Y – (–) W)
email: info@motomatrix.co.uk / www.motomatrix.co.uk
Action
1
I947H1110131-01
2
I947H1110132-01
(B)
3
(A)
I947H1110097-01
Engine General Information and Diagnosis:
Yes
Replace the ECM with a
known good one, and
inspect it again.
1A-117
No
Go to Step 5.