3) Check the resistance between the terminals of the
EVAP system purge control solenoid valve. If the
resistance is not within the standard range, replace
the EVAP system purge control solenoid valve with a
new one.
Special tool
(A): 09900–25008 (Multi circuit tester set)
Tester knob indication
Resistance (Ω)
EVAP system purge control solenoid valve
resistance
Approx. 32 Ω at 20 °C (68 °F)
(A)
email: info@motomatrix.co.uk / www.motomatrix.co.uk
Fuel Shut-off Valve
WARNING
!
Gasoline and gasoline vapor is toxic. A small
amount of fuel remains in the fuel shut-off
valve when checking it. Do not swallow the
fuel when blowing the fuel shut-off valve.
1) When air is blown into the fuel shut-off valve with its
side "A" positioned upward, the air can pass through
to the canister side.
2) When air is blown into the fuel shut-off valve with its
side "A" positioned sideways, the air cannot pass
I947H1120040-01
through to the canister side. If the fuel shut-off valve
operates otherwise, it must be replaced.
Emission Control Devices:
"A"
"A"
1B-15
I823H1120037-01
I823H1120038-02