System Commands
Context
show
Description
This command displays the time since the system started.
Output
Uptime Output — The following table describes uptime output fields.
Sample Output
A:ALA-1# show uptime
System Up Time
A:ALA-1#
sync-if-timing
Syntax
sync-if-timing
Context
show>system
Description
This command displays synchronous interface timing information.
Output
System Timing Output — The following table describes sync-if-timing output fields.
Page 494
Table 39: System Timing Output Fields
Label
System Up Time
Label
System Status CPM A
Reference Input Mode
Reference Order
Reference Input 1
Admin Status
Qualified For Use
7210 SAS M, T, X, R6 Basic System Configuration Guide
Displays the length of time the system has been up in days,
hr:min:sec format.
: 11 days, 18:32:02.22 (hr:min:sec)
Indicates the system status of CPM A.
Indicates the reference input mode.
Indicates the reference order.
Displays information about reference input 1
Indicates the Admin status of reference input 1.
down — Indicates the ref1 or ref2 configuration is administratively
shutdown.
up — Indicates the ref1 or ref2 configuration is administratively
enabled.
diag — Indicates the reference has been forced using the force-refer-
ence command.
Indicates if the reference input 1 is qualified for use