Alcatel-Lucent 7210 SAS M Configuration Manual page 342

Service access switch
Hide thumbs Also See for 7210 SAS M:
Table of Contents

Advertisement

System Alarm Commands
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
owner owner — The owner identifies the creator of this alarm. It defaults to "TiMOS CLI". This
Configuration example:
alarm 3 variable-oid ifInOctets.184582144 interval 20 sample-type delta start-alarm
either rising-event 5 rising-threshold 10000 falling-event 5 falling-threshold 9000
owner "TiMOS CLI"
cflash-cap-alarm
Syntax
cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The
severity level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
Page 342
Guide
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated 'startup-alarm' is equal to 'falling' or 'either'.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value rises above this threshold and reaches greater than or equal the rising-
threshold threshold value.
Default
0
Values
-2147483648 — 2147483647
parameter is defined primarily to allow entries that have been created in the RMON-MIB
alarmTable by remote SNMP managers to be saved and reloaded in a CLI configuration file. The
owner will not normally be configured by CLI users and can be a maximum of 80 characters
long.
Default
TiMOS CLI
Values
cf1:, cf2 (only on 7210 SAS-T), cf1-A:
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated 'startup-alarm' is equal to 'rising' or 'either'.
7210 SAS M, T, X, R6 Basic System Configuration

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents