Advertisement

memory-use-alarm
Syntax
memory-use-alarm rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no memory-use-alarm
Context
config>system>thresholds
Description
The memory thresholds are based on monitoring the TIMETRA-SYSTEM-MIB sgiMemoryUsed
object. This object contains the amount of memory currently used by the system. The severity level is
Alarm.
The no form of this command removes the configured memory threshold warning.
Parameters
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
interval seconds — Specifies the polling period over which the data is sampled and compared with
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
7210 SAS M, T, X, R6 Basic System Configuration Guide
The absolute sample type method is used.
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
Default
0
Values
-2147483648 — 2147483647
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold threshold value.
Default
0
Values
-2147483648 — 2147483647
the rising and falling thresholds.
Values
1 — 2147483647
Values
log — In the case of log, an entry is made in the RMON-MIB log table for each
event occurrence. This does not create an OS logger entry. The RMON-MIB log
table entries can be viewed using the CLI command.
trap — In the case of trap, a TiMOS logger event is generated. The TiMOS logger
utility then distributes the notification of this event to its configured log