System Alarm Commands
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created. If
Configuration example:
memory-use-warn
Syntax
memory-use-warn rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no memory-use-warn
Context
config>system>thresholds
Description
The memory thresholds are based on monitoring MemoryUsed object. This object contains the
amount of memory currently used by the system. The severity level is Alarm.
The absolute sample type method is used.
The no form of this command removes the configured compact flash threshold warning.
Parameters
rising-threshold threshold — The rising-threshold specifies a threshold for the sampled statistic.
Page 348
Guide
destinations which may be CONSOLE, telnet session , memory log, cflash file,
syslog, or SNMP trap destinations logs.
both — In the case of both, both a entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — In the case of none, no action is taken.
Default
both
the first sample is greater than or equal to the rising threshold value and startup-alarm is equal to
rising or either, then a single rising threshold crossing event is generated. If the first sample is
less than or equal to the falling threshold value and startup-alarm is equal to falling or either, a
single falling threshold crossing event is generated.
Values
rising, falling, either
Default
either
memory-use-alarm rising-threshold 50000000 falling-threshold 45999999 interval 500 rmon-
event-type both start-alarm either
When the current sampled value is greater than or equal to this threshold, and the value at the last
sampling interval was less than this threshold, a single threshold crossing event will be
generated. A single threshold crossing event will also be generated if the first sample taken is
greater than or equal to this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.