Communications
Note 2. No data can be written to multi-function input.
Note 3. The unit of setting of the broadcast message is different from that in the DSR
message to communicate with a single Slave.
D RUN Command (Register 0001 Hex)
Bit No.
0
1
2
3
4 to 15

7-6-2 Monitor Functions

Register No.
(Hex)
0020
Status signal
0021
Fault status 1
0022
Data link status
0023
Frequency reference
0024
Output frequency
0025 to 0026
Not used
0027
Output current
0028
Output voltage
0029
Fault status (see note 2)
002A
Warning (see note 2)
002B
Input terminal status
002C
Inverter status
002D
Output terminal status
002E
002F to 0030
not used
0031
Main circuit DC voltage
0032
Torque reference
0033 to 0034
Not used
0035
0036
Not used
0037
Output power
0038
PID feedback
7-26
RUN command (1: RUN)
Forward/Reverse (1: Reverse)
External fault (1: External fault EF0)
Fault reset (1: Fault reset)
Not used
Function
Function
Description
Refer to the following corresponding table.
Refer to the following corresponding table.
Refer to the following corresponding table.
According to the set value in n152.
According to the set value in n152.
---
Read based on 1 A as 10.
Read based on 1 V as 1.
Refer to the following corresponding table.
Refer to the following corresponding table.
Refer to the following corresponding table.
Refer to the following corresponding table.
Refer to the following corresponding table.
Refer to the following corresponding table.
---
Read based on 1 V as 1.
Read based on ±1% as ±1 and the rated
motor torque is 100%.
---
Read based on 1 [h] as 1
---
Read based on ±1 kW as ±100.
Read based on 1% as 10 and a value
equivalent to the maximum frequency as
100%.