D Braking Resistors and Braking Resistor Units for 400-V-class Inverters
Inverter
Braking Resistor
3G3MV-
(3% usage rate ED)
PERF150WJ751 (750 W)
PERF150WJ751 (750 W)
A4002
A4004
A4007
A4015
PERF150WJ401 (400 W)
A4022
PERF150WJ301 (300 W)
A4030
PERF150WJ401 (400 W) ´ 2 PLKEB43P7 (150 W, 390 W)
A4040
PERF150WJ401 (400 W) ´ 2 PLKEB43P7 (150 W, 390 W)
A4055
PERF500WJ360T (36 W)
A4075
PERF101WJ360T (36 W)
Note Do not use resistances less than than the minimum connection resistance value.
Doing so may damage the Inverter.
Note The usage rate is shown as a percentage of the braking time in one cycle. If one
cycle is 10 seconds, for example, one second of braking is possible using a Brak-
ing Resistor Unit (10% usage rate ED). If the usage rate is to be exceeded, a de-
tailed regeneration energy calculation will be required.
D The dimensions of a Braking Resistor Unit
Model No.
Model No.
3G3IV-
3G3IV-
PLKEB40P7
105
PLKEB41P5
130
PLKEB42P2
130
PLKEB43P7
130
PLKEB45P5
250
PLKEB47P5
250
3G3IV-
Dimensions (mm)
A
B
275
350
350
350
350
350
Braking Resistor Unit
(10% usage rate ED)
3G3IV-
PLKEB40P7 (750 W, 70 W)
PLKEB40P7 (750 W, 70 W)
PLKEB41P5 (400 W, 260 W)
PLKEB42P2 (250 W, 260 W)
PLKEB45P5 (100 W, 520 W)
PLKEB47P5 ( 75 W, 780 W)
C
D
50
260
75
335
75
335
75
335
200
335
200
335
Chapter 2
Minimum
connection
resistance
750 W
750 W
510 W
240 W
200 W
100 W
100 W
32 W
32 W
Mounting Screws
M5x3
M5x4
M5x4
M5x4
M6x4
M6x4
Weight
Weight
(kg)
(kg)
3.0
4.5
4.5
5.0
7.5
8.5