Specifications

Control
Harmonic-current
charac-
charac-
countermeasures
teristics
teristics
Control method
Carrier frequency
Frequency control
range
Frequency precision
(temperature
characteristics)
Frequency setting
resolution
Output frequency
resolution
Overload capacity
External frequency
set signal
Acceleration/decel-
eration time
Braking torque
Voltage/frequency
characteristics
Protec-
Protec-
Motor protection
tive
tive
Instantaneous
func-
overcurrent
tions
protection
Overload protection
Overvoltage
protection
Undervoltage
protection
Momentary power
interruption
compensation
(selection)
Cooling fan
overheating
Grounding
protection
Charge indicator
(RUN indicator)
DC reactor (option) connection possible
Sine wave PWM (V/f control)
2.5 to 10.0 kHz (in vector control)
0.1 to 400 Hz
Digital commands: ±0.01% (--10°C to 50°C)
Analog commands: ±0.5% (25°C ± 10°C)
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz (100 Hz or
over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
0.01 Hz
150% of rated output current for 1 min
Selectable with FREQ adjuster: 0 to 10 VDC (20 kW), 4 to 20 mA
(250 W), and 0 to 20 mA (250 W)
0.01 to 6,000 s (Independent acceleration and deceleration time
settings: 2 types)
Approx. 20% (125 to 150% possible with braking resistor)
Set voltage vector control/user V/f pattern
Protection by electronic thermal
Stops at approx. 250% of rated output current
Stops in 1 min at approximately 150% of rated output current
Stops when main-circuit DC voltage is approximately 410 V
Stops when main-circuit DC voltage is approximately 200 V
(160 V for single-phase 200-VAC model)
Stops for 15 ms or more. By setting the Inverter to momentary
power interruption mode, operation can be continued if power is
restored within approximately 0.5 s.
Detects at 110°C ± 10°C
Protection at overcurrent detection level
Lit when the main circuit DC voltage is approximately 50 V or
less.