Omron SYSDRIVE 3G3MV User Manual page 127

Multi-function compact inverter sysdrive 3g3mv series
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

Basic Operation
Acceleration Time 1
n019
Setting
0.0 to 6,000 (s) (see note 1)
range
n020
Deceleration Time 1
Setting
0.0 to 6,000 (s) (see note 1)
range
n021
Acceleration Time 2
Setting
0.0 to 6,000 (s) (see note 1)
range
Deceleration Time 2
n022
Setting
0.0 to 6,000 (s) (see note 1)
range
Note 1. The setting unit of acceleration or deceleration time is determined by the set
value in n018 (acceleration/deceleration time unit).
n018 set to 0: Setting range from 0.0 to 6,000 (0.0 through 999.9 s or 1,000
through 6,000 s)
n018 set to 1: Setting range from 0.00 to 600.0 (0.0 through 99.99 s or 100.0
through 600.0 s)
Note 2. When n018 is set to 1, the default value of acceleration or deceleration time will
be set to 10.00.
H S-shape Acceleration/Deceleration Characteristic (n023)
·Trapezoidal and S-shape acceleration and deceleration are available. Using the
S-shape characteristic function for acceleration and deceleration can reduce shock to
the machinery when stopping or starting.
·Any one of three S-shape acceleration/deceleration times (0.2, 0.5, and 1.0 s) is
selectable.
S-shape Acceleration/
n023
Deceleration Characteristic
Setting
0 to 3
range
5-28
Register 0113
Hex
Unit of
0.1 s
setting
(see
note 1)
Register 0114
Hex
Unit of
0.1 s
setting
(see
note 1)
Register 0115
Hex
Unit of
0.1 s
setting
(see
note 1)
Register 0116
Hex
Unit of
0.1 s
setting
(see
note 1)
Register 0117
Hex
Unit of
1
setting
Chapter 5
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
No
operation
Default setting
0