Basic Operation

5-10 Multi-function I/O

5-10-1 Multi-function Input
The 3G3MV incorporates seven multi-function input terminals (S1 through
S7). Inputs into these terminals have a variety of functions according to the
application.
H Multi-function digital Input (n050 through n056)
n050
Multi-function digital Input 1 (S1)
Setting
1 to 25 (for 26, see note)
range
Multi-function digital Input 2 (S2)
n051
Setting
1 to 25 (for 26, see note)
range
Multi-function digital Input 3 (S3)
n052
Setting
0 to 25 (for 26, see note)
range
n053
Multi-function digital Input 4 (S4)
Setting
1 to 25 (for 26, see note)
range
Multi-function digital Input 5 (S5)
n054
Setting
1 to 25 (for 26, see note)
range
Multi-function digital Input 6 (S6)
n055
Setting
1 to 25 (for 26, see note)
range
Multi-function digital Input 7 (S7)
n056
Setting
1 to 25, 34, and 35
range
(for 26, see note)
Note Set value 26 is available for 5.5kW and 7.5kW Inverters only.
5-32
Register 0132
Changes during
Hex
operation
Unit of
1
Default setting
setting
Register 0133
Changes during
Hex
operation
Unit of
1
Default setting
setting
Register 0134
Changes during
Hex
operation
Unit of
1
Default setting
setting
Register 0135
Changes during
Hex
operation
Unit of
1
Default setting
setting
Register 0136
Changes during
Hex
operation
Unit of
1
Default setting
setting
Register 0137
Changes during
Hex
operation
Unit of
1
Default setting
setting
Register 0138
Changes during
Hex
operation
Unit of
1
Default setting
setting
Chapter 5
No
1
No
2
No
3
No
5
No
6
No
7
No
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents