List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
n161
01A1
Power detec-
tion width for
probe opera-
tion switching
n162
01A2
Power detec-
tion filter con-
stant
n163
01A3
PID output
gain
n164
01A4
PID feedback
input block
selection
n165
01A5
Installed
braking resis-
tor overheat-
ing protection
(see note 1)
10-28
Description
Set the detection width of power that
sets the Inverter into probe operation.
Set the width in percentage based on
the power to be detected as 100%.
Note Normally, the default setting
does not need to be changed.
Note The Inverter will operate with a
power detection width of 10% if
the value is set to 0.
Set the filter time constant of the
power detection block of the Inverter
operating in probe operation.
Filter time constant (ms) = Set value
in n162 x 4 (ms)
Note Normally, the default setting
does not need to be changed.
Note The Inverter will operate with a
time constant of 20 ms if the
value is set to 0.
Set the rate by which PID control
value is multiplied for PID control.
Note Normally, the default setting
does not need to be changed.
Set the feedback input block for PID
control detection.
0: Frequency reference control
terminal for voltage input (0 to
10 V) is enabled.
1: Frequency reference control
terminal for current input (4 to
20 mA) is enabled.
2: Frequency reference control
terminal for current input (0 to
20 mA) is enabled.
3: Multi-function analog voltage input
(0 to 10 V) is enabled.
4: Multi-function analog current input
(0 to 20 mA) is enabled.
5: Pulse train reference control
terminal is enabled.
Note Make sure that the target value
input and feedback value input
do not overlap with each other.
0: Overheating protection disabled
1: Overheating protection enabled
Chapter 10
Set-
Unit
Default
setting
ting
of
range
set-
ting
0 to
1%
10
100
0 to
1 (4
5
255
ms)
0.0 to
0.1
1.0
25.0
0 to 5
1
0
0,1
1
0
Changes
Ref-
during
er-
opera-
ence
tion
page
No
6-11
No
6-12
No
6-21
No
6-21
No
---

Hide quick links: