Omron SYSDRIVE 3G3MV User Manual page 313

Multi-function compact inverter sysdrive 3g3mv series
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
n002
0102
Control mode
selection
n003
0103
Operation
command
selection
Description
Used to select the control mode of the
Inverter.
0: V/f control mode
1: Vector control mode (open loop)
Note The set value in n002 is not ini-
tialized with n001 set to 8 or 9.
Note Each of the following parame-
ters is initialized according to
the preset control mode. The
default setting varies with the
control mode.
n014: Middle output frequency
n015: Middle output frequency volt-
age
n016: Minimum output frequency
n017: Minimum output frequency
voltage
n104: Torque compensation primary
delay time constant
n111: Slip compensation gain
n112: Slip compensation primary
delay time constant
See the reference pages for details.
Used to select the input method for
the RUN and STOP commands in
remote mode.
0: The STOP/RESET Key on the digi-
tal Operator is enabled.
1: Multi-function input is enabled
through the control circuit terminals
in 2- or 3-wire sequence.
2: RS-422/485 communications are
enabled.
3: Input is enabled from the optional
CompoBus/D Communications
Unit.
Note The
RUN
command
through key sequences on the
Digital Operator is acceptable
in local mode.
Set-
Unit
Default
setting
ting
of
range
set-
ting
0, 1
1
0
0 to 3
1
0
only
Chapter 10
Changes
Ref-
during
er-
opera-
ence
tion
page
No
5-3
No
5-11
10-3