Advertisement

Basic Operation
This section explains the basic settings required to operate and stop the
Inverter.
The settings of parameters described here will be sufficient for simple
Inverter operations.
First, make these basic settings, then skip to the explanations of those spe-
cial functions, even when your application requires special functions, such
as energy-saving control, PID control, stall prevention, carrier frequency
setting, overtorque detection, torque compensation, slip compensation.
Refer to Chapter 6 Advanced Operation.

5-1 Initial Settings

·The following initial settings are required.
Parameter Write-prohibit Selection/Parameter Initialization (n001): Set n001 to 4 so
that n001 through n179 can be set or displayed.
Control Mode Selection (n002): Set to V/f or vector control mode according to the
application.
5-1-1 Setting the Parameter Write-prohibit
Selection/Parameter Initialization (n001)
·Set n001 to 4 so that n001 through n179 can be set or displayed.
n001
Parameter Write-prohibit
Selection/Parameter Initialization
Setting
0 to 9
range
Note This parameter makes it possible to write-prohibit parameters, change the
parameter set or displayed range, or initialize all parameters to default values.
5-2
Register 0101
Changes during
Hex
operation
Unit of
1
Default setting
setting
Chapter 5
No
1