Basic Operation

5-5 Selecting the Operation Command

The following description provides information on how to input operation
commands to start or stop the Inverter or change the direction of rotation of
the Inverter.
Two types of command input methods are available. Select either one of
them according to the application.
H Selecting the Operation Mode (n003)
·Select the method of operation mode input to start or stop the Inverter.
·The following method is enabled in remote mode only. The command can be input
through key sequences on the Digital Operator.
Operation Command
n003
Selection
Setting
0 to 3
range
Set Values
Value
0
The RUN and STOP/RESET Keys of the Digital Operator are enabled.
1
Multi-function input in 2- or 3-wire sequence through the control circuit
terminals is enabled.
2
MODBUS RS-422/485 communications are enabled.
3
Input from optional the CompoBus/D Communications Unit is enabled.
H Selecting the STOP/RESET Key Function (n007)
·When parameter n003 is not set to 0, set whether or not to use the STOP/RESET Key
of the Digital Operator to stop the Inverter in remote mode. The STOP/RESET Key is
always enabled in local mode regardless of the setting in n003.
STOP Key Function Selection
n007
Setting
0, 1
range
Set Values
Value
0
The STOP/RESET Key of the Digital Operator is enabled.
1
The STOP/RESET Key of the Digital Operator is disabled.
Register 0103
Changes during
Hex
operation
Unit of
1
Default setting
setting
Description
Register 0107
Hex
Unit of
1
setting
Description