Communications
H Creating a Sequence
1. Click on New Protocol with the left button of the mouse. Then click on a blank space
with the right button of the mouse.
2. Select New Send & Recv Sequence.
The following table will appear. Set the parameters related to the sequence in the
table.
*
#
Send & Recv
sequence
000
Inverter I/O
Send & Recv
#
Sequence number. The sequence number is automatically set.
Send & Recv Sequence
The label (name) of the sequence. Input an appropriate, easy-to-distinguish name.
Link Word
Set the area for sharing the data between the Programmable Controller and Commu-
nications Board.
Note In this example, the link word is specified by the operand of the PMCR instruction.
Therefore, no link word is set here.
Transmission Control Parameter
Set the control method, such as flow control.
Note Select only model control for communications with the 3G3MV.
Response
A method to write reception data to the I/O memory of the Programmable Controller.
Note Select "notify by scan" for communications with the 3G3MV.
Link word
Transmis-
sion control
parameter
---
Set (Setting
required)
Response
Timer Tr
Scan
0.5
Chapter 7
Timer
Timer
Tfr
Tfs
0.5
0.5