Advanced Operation
H Frequency Detection
·The multi-function outputs (n057 to n059) must be set to the following in order to issue
an output indicating that the frequency reference and the output frequency agree.
Set value: 2 for frequency agree
Frequency Detection Operation
Output
frequency
Frequency
detection
H Frequency Detection Levels 1 and 2
·The parameters in n057 to n059 for multi-function output must be set for frequency
detection output.
Set value: 4 for frequency detection level 1 (Output frequency
Set value: 5 for frequency detection level 2 (Output frequency
·Set the frequency detection level in n095.
Frequency Detection Level
n095
Setting
0.00 to 400.0 (Hz)
range
Set Values
·Set the frequency to be detected.
Detection width ±2 Hz Reset width ±4 Hz
Register 015F
Unit of
setting
Frequency reference
Changes during
Hex
operation
0.01 Hz
Default setting
Chapter 6
Time
Time
n095)
n095)