List of Parameters
Para
Reg-
Name
me-
ister
ter
No.
No.
n098
0162
Overtorque
detection
level
n099
0163
Overtorque
detection
time
n100
0164
UP/DOWN
frequency
selection
n101
0165
Speed
search de-
celeration
time
n102
0166
Speed
search op-
eration lev-
el
n103
0167
Torque
compensa-
tion gain
n104
0168
Torque
compensa-
tion pri-
mary delay
time con-
stant
n105
0169
Torque
compensa-
tion core
loss
n106
016A
Rated
motor slip
n107
016B
Motor
phase to
neutral
resistance
10-20
Description
Used to set overtorque detection level.
Detection from output torque: Set in percent-
age based on the rated motor torque as 100%.
Detection from output current: Set in percent-
age based on the rated Inverter output current
as 100%.
Used to set the detection time of overtorque.
Used to store the adjusted frequency reference
with the UP/DOWN function.
0: Frequency not stored
1: Frequency stored
The frequency must be on hold for 5 s or
more.
Note
Only applicable for 200/400V,
5.5/7.5kW models
Note Applicable
for
No. 010024 or later
Note
Only applicable for 200/400V,
5.5/7.5kW models
Note Applicable
for
No. 010024 or later
Used to set the gain of the torque compensa-
tion function.
Note The default setting does not need any
changes in normal operation.
Set the response speed of the torque com-
pensation function.
Note Normally, the default setting does not
need to be changed.
Set the core loss of the motor in use.
Note Normally, the default setting does not
need to be changed.
Note This parameter is enabled in V/f control
mode only.
Used to set the rated slip value of the motor in
use.
Note Used as the constant of the slip com-
pensation function.
Set this parameter to 1/2 of the phase to neu-
tral resistance or phase-to-phase resistance of
the motor.
Note This parameter is used as a vector con-
trol constant.
Set-
ting
range
30 to
200
0.1 to
10.0
0, 1
0.0 to
10.0
software
version
0 to
200
software
version
0.0 to
2.5
0.0 to
25.5
0.0 to
6,550
0.0 to
20.0
0.000
to
65.50
Chapter 10
Unit
Defaul
Chan-
t set-
of
ges dur-
ting
set-
ing
ting
opera-
tion
1%
160
No
0.1 s
0.1
No
1
0
No
0.1s
2.0
No
1%
150
No
0.1
1.0
Yes
0.1 s
0.3
No
0.1 W
Varies
No
with
the
capac-
ity.
0.1
Varies
Yes
Hz
with
the
capac-
ity.
0.001
Varies
No
with
W
the
capac-
ity
Ref-
er-
ence
page
6-36
6-36
6-48
---
---
6-37
6-37
6-38
6-39
5-6
6-2