Omron SYSDRIVE 3G3MV User Manual page 327

Multi-function compact inverter sysdrive 3g3mv series
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

List of Parameters
Para
Reg-
Name
me-
ister
ter
No.
No.
n071
0147
Multi-func-
tion analog
current
input gain
n072
0148
Multi-func-
tion analog
current
input bias
n073
0149
Multi-func-
tion analog
current
input filter
time con-
stant
n074
014A
Pulse train
frequency
reference
gain
n075
014B
Pulse train
frequency
reference
bias
n076
014C
Pulse train
frequency
reference
input filter
time
constant
n077
014D
Multi--func-
tion analog
input termi-
nal func-
tion selec-
tion
n078
014E
Multi--func-
tion analog
input termi-
nal selec-
tion
n079
014F
Multi-func-
tion input
frequency
bias
Description
Set the input characteristics of multi-function
analog current input.
Gain:Set the frequency of maximum analog
input (20 mA) in percentage based on the
input (20 mA) in percentage based on the
maximum frequency as 100%.
maximum frequency as 100%.
Bias: Set the frequency of minimum analog
input (0 V) in percentage based on the
maximum frequency as 100%.
Set a primary delay digital filter for multi-function
analog current input.0.00 to 2.00
Set the input characteristics of pulse train input.
Gain:Set the gain in percentage based on the
maximum frequency of the pulse train
input scale in n149 as 100%.
input scale in n149 as 100%.
Bias: Set the bias in percentage for frequency
reference input at 0-Hz pulse train input
based on the maximum frequency as
100%.
Sets the pulse train input's primary-delay digital
filter for frequency reference.
Selects the function allocated to the multi-func-
tion analog input terminal.
0: Disable multi-function analog input function.
1: Auxiliary frequency reference
2: Frequency gain
3: Frequency bias
4: Output voltage bias
Note: When setting "3," also set the standard
value for the bias in n079.
Selects whether voltage input or current input is
to be used.
0: Enable multi-function analog voltage input
(and disable current input).
1: Enable multi-function analog current input
(and disable voltage input).
When "3" is set for n077, set the standard value
for the bias as a percentage, taking the maxi-
mum frequency as 100%.
Chapter 10
Set-
Unit
Defaul
t set-
ting
of
ges dur-
ting
range
set-
ting
--255
1%
100
Yes
to 255
--100
1%
0
Yes
to 100
0.00
0.01 s 0.10
Yes
to
2.00
--255
1%
100
Yes
to 255
--100
1%
0
Yes
to 100
0.00
0.01 s 0.10
Yes
to
2.00
0 to 4
1
0
No
0,1
1
0
No
0 to
1%
10
No
50
Chan-
Ref-
er-
ing
ence
opera-
page
tion
NO TAG
NO TAG
NO TAG
5-25
5--24
5--25
5--15
5--15
5--15
10-17