Selecting The Reverse Rotation-Prohibit - Omron SYSDRIVE 3G3MV User Manual

Multi-function compact inverter sysdrive 3g3mv series
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

Basic Operation

5-8 Selecting the Reverse Rotation-prohibit

This parameter is used to specify whether to enable or disable the reverse
rotation command sent to the Inverter from the control circuit terminals or
Digital Operator.
The parameter should be set to "not accept" when the Inverter is applied to
systems that prohibit the reverse rotation of the Inverter.
H Selecting the Reverse Rotation-prohibit (n006)
n006
Reverse Rotation-prohibit
Selection
Setting
0, 1
range
Set Values
Value
0
Accept
1
Not accept
5-30
Register 0106
Hex
Unit of
1
setting
Description
Chapter 5
Changes during
No
operation
Default setting
0