List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
n019
0113
Acceleration
time 1
n020
0114
Deceleration
time 1
n021
0115
Acceleration
time 2
n022
0116
Deceleration
time 2
n023
0117
S-shape
acceleration/
deceleration
characteristic
10-6
Description
Acceleration time: The time required
to go from 0% to 100% of the maxi-
mum frequency.
Deceleration time: The time required
Deceleration time: The time required
to go from 100% to 0% of the maxi-
mum frequency.
Note
Note
The actual acceleration or
The actual acceleration or
deceleration time is obtained
from the following formula.
Acceleration/Deceleration
time = (Acceleration/Decel-
time = (Acceleration/Decel-
eration time set value) ´ (Fre-
quency reference value) ¸
(Max. frequency)
Used to set S-shape acceleration/de-
celeration characteristics.
0: No S-shape acceleration/decelera-
tion (trapezoidal acceleration/de-
celeration)
1: S-shape acceleration/deceleration
characteristic time 0.2 s
2: S-shape acceleration/deceleration
characteristic time 0.5 s
3: S-shape acceleration/deceleration
characteristic time 1.0 s
Note When the S-shape accelera-
tion/deceleration characteristic
time is set, the acceleration and
deceleration
times
lengthened according to the
S-shape at the beginning and
end of acceleration/decelera-
tion.
Set-
Unit
ting
of
range
set-
ting
0.0 to
0.1 s
(chan
6,000
ge in
n018)
n018)
0 to 3
1
will
be
Chapter 10
Changes
Ref-
Default
setting
during
er-
opera-
ence
tion
page
10.0
Yes
5-27
10.0
Yes
5-27
10.0
Yes
5-27
10.0
Yes
5-27
0
No
5-28