Basic Operation
For n077, select from the following five functions allocated to the multi-function analog input
·
terminal.
n077 Set Values
Value
Name
Multi-function
0
Analog Input
Function Disable
Auxiliary
1
Frequency
Reference
Frequency Gain
2
(See note 1.)
Frequency Bias
3
(See note 1.)
4
Output Voltage
Bias
The frequency reference gain (n060) and frequency reference bias (n061) pa-
Note 1.
rameter settings are enabled. If "frequency gain" is set for the multi-function
analog input, it is multiplied by n060; if "frequency bias" is set, it is added to
n061.
The relationship between the multi-function analog input's input voltage and
Note 2.
control variable is shown for when the frequency reference and multi-function
analog input gain are 100%, and when the bias setting is 0%.
For n078, select whether select whether voltage inputs or current inputs are to be
·
used.
Value
0
Enable multi-function analog voltage inputs. (Disable current inputs.)
1
Enable multi-function analog current inputs. (Disable voltage inputs.)
5-16
Disables multi-function analog inputs.
Set "0" when setting multi-function inputs with n004
(Frequency Reference Selection) or n164 (PID Feedback
Input Block Selection). If this function is allocated for both, an
error (err or oP6) will be generated.
Sets the terminal to be used as a second analog frequence
reference terminal. The analog input from the multi-function
analog input becomes the frequency reference in place of
Frequency Reference 2. Toggle the two analog inputs with
the multi-function input's multi-step speed references.
When this function is set, Frequency Reference 2 (n025) is
ignored.
Adjusts the gain for frequency references that are input to the
frequency reference input (analog) terminal.
0 to 10 V (4 mA, or 0 mA to 20 mA): 0x to 2x (See note 2.)
Adjusts the bias for frequency references that are input to the
frequency reference input (analog) terminal.
0 to 10 V (4 mA, or 0 mA to 20 mA): --n079 SV to +n079 SV
(See note 2.)
Adjusts the Inverter's output voltage bias. The bias value that
is input is added to the output voltage value for the normal
V/f setting.
0 to 10 V (4 mA, or 0 mA to 20 mA): 0 V to +100 V
(See note 2.)