Preparing for Operation and Monitoring
Display
Name
Copy error
cpe
Copy voltage error Main-circuit low voltage is
cye
Capacity error
uae
ife
Communications
error
3-20
Probable cause
An attempt was made to
copy or verify the parameter
set values while the
Inverters are different to
each other in voltage or
control mode.
detected while the Inverter
was copying the parameter
set values.
An attempt was made to
verify the parameter set
values while the Inverters
were different to each other
in capacity.
A communications error
resulted between the
Inverter and Digital
Operator.
Chapter 3
Remedy
Check that the Inverters are
the same in voltage and
control mode. If either of
them is different, no
parameter set values can be
either copied or verified.
If the Inverters are different
only in control mode, retry
after changing the mode of
the Inverter to which the
parameter set values are to
be written.
Retry after checking that the
voltage of the main circuit is
normal.
To continue verifying the
parameter set values, press
the Enter Key.
To cancel the operation,
press the STOP/RESET
Key.
Retry after checking the
connection between the
Inverter and Digital
Operator.