Basic Operation
5-4

Selecting the Operation Command

The following description provides information on how to input operation commands to
start or stop the Inverter or change the direction of rotation of the Inverter.
Three types of command input methods are available. Select either one of them accord-
ing to the application.
H Selecting the Operation Mode (n02)
• Select the method of operation mode input to start or stop the Inverter.
• The following method is enabled in remote mode only. The command can be input through key se-
quences on the Digital Operator.
n02
Operation Command Selection
Setting
0 to 2
range
Set Values
Value
0
The RUN and STOP/RESET Keys of the Digital Operator are enabled.
1
Multi-function input in 2- or 3-wire sequence through the control circuit terminals is enabled.
2
Operation commands via RS-422/485 communications are enabled.
H Selecting the STOP/RESET Key Function (n06)
• When parameter n02 is set to 1, set whether or not to use the STOP/RESET Key of the Digital Opera-
tor to stop the Inverter in remote mode. The STOP/RESET Key is always enabled in local mode re-
gardless of the setting in n02.
n06
STOP Key Function Selection
Setting
0, 1
range
Set Values
Value
0
The STOP/RESET Key of the Digital Operator is enabled.
1
The STOP/RESET Key of the Digital Operator is disabled. This setting is available only when
the Digital Operator is selected for operation command input.
Unit of
1
setting
Description
Unit of
1
setting
Description
Chapter 5
Changes during
No
operation
Default setting
0
Changes during
No
operation
Default setting
0